LIST OF FIGURES
1-159. Graphs showing:
- Display of ordinary least-squares regression equation derived for sodium
- Alkalinity, whole-water recoverable, (electrometric titration) data from
the National Water Quality Laboratory
- Aluminum, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Aluminum, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Aluminum, whole-water recoverable, (direct current plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Antimony, dissolved, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Antimony, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Arsenic, dissolved, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Arsenic, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry, U.S. Environmental Protection Agency) data from the National
Water Quality Laboratory
- Arsenic, whole-water recoverable, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Barium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Barium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Beryllium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Beryllium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Boron, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Boron, whole-water recoverable, (direct current plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Cadmium, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Cadmium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Cadmium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Cadmium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Calcium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Chloride, dissolved, (ion chromatography) data from the National Water
Quality Laboratory
- Chloride, dissolved, (ion chromatography, low level) data from the
National Water Quality Laboratory
- Chromium, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Chromium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Chromium, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Chromium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Cobalt, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Cobalt, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Cobalt, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Cobalt, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Copper, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Copper, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Copper, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Copper, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Dissolved solids, dissolved, (gravimetric) data from the National Water
Quality Laboratory
- Fluoride, dissolved, (ion chromatography, low level) data from the
National Water Quality Laboratory
- Fluoride, dissolved, (ion-selective electrode) data from the National
Water Quality Laboratory
- Iron, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Iron, whole-water recoverable, (flame-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Lead, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Lead, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Lead, dissolved, (inductively coupled plasma-mass spectrometry) data from
the National Water Quality Laboratory
- Lead, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Lithium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Lithium, whole-water recoverable, (flame-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Magnesium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Manganese, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Manganese, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Manganese, whole-water recoverable, (flame-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Mercury, dissolved, (cold vapor-atomic absorption spectrophotometry) data
from the National Water Quality Laboratory
- Mercury, whole-water recoverable, (cold vapor-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Molybdenum, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Molybdenum, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Molybdenum, dissolved, (inductively coupled plasma-mass spectrometry)
data from the National Water Quality Laboratory
- Molybdenum, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Nickel, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Nickel, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Nickel, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Nickel, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Potassium, dissolved, (flame-atomic absorption spectrophotometry) data
from the National Water Quality Laboratory
- Potassium, dissolved, (flame-atomic absorption spectrophotometry, low
level) data from the National Water Quality Laboratory
- Selenium, dissolved, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Selenium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry, U.S. Environmental Protection Agency) data from the National
Water Quality Laboratory
- Selenium, whole-water recoverable, (hydride generation-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Silica, dissolved, (colorimetric) data from the National Water Quality
Laboratory
- Silica, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Silver, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Silver, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Silver, dissolved, (inductively coupled plasma-mass spectrometry) data
from the National Water Quality Laboratory
- Silver, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the National Water Quality Laboratory
- Sodium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Specific conductance, whole-water recoverable, (electrometric, low level)
data from the National Water Quality Laboratory
- Strontium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Sulfate, dissolved, (ion chromatography) data from the National Water
Quality Laboratory
- Vanadium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Zinc, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the National Water Quality Laboratory
- Zinc, dissolved, (inductively coupled plasma-mass spectrometry) data from
the National Water Quality Laboratory
- Zinc, whole-water recoverable, (flame-atomic absorption spectrophotometry)
data from the National Water Quality Laboratory
- Ammonia as nitrogen, dissolved, (colorimetric) data from the National
Water Quality Laboratory
- Ammonia as nitrogen, dissolved, (colorimetric, low level) data from the
National Water Quality Laboratory
- Ammonia as nitrogen, dissolved, (U.S. Environmental Protection Agency)
data from the National Water Quality Laboratory
- Ammonia plus organic nitrogen as nitrogen, dissolved, (micro-Kjeldahl
digestion, automated segmented flow, colorimetric) data from the National Water
Quality Laboratory
- Ammonia plus organic nitrogen as nitrogen, dissolved, (U.S. Environmental
Protection Agency) data from the National Water Quality Laboratory
- Ammonia plus organic nitrogen as nitrogen, whole-water recoverable,
(micro-Kjeldahl digestion, automated segmented flow, colorimetric) data from the
National Water Quality Laboratory
- Ammonia plus organic nitrogen as nitrogen, whole-water recoverable, (U.S.
Environmental Protection Agency) data from the National Water Quality Laboratory
- Nitrate plus nitrite as nitrogen, dissolved, (colorimetric) data from the
National Water Quality Laboratory
- Nitrate plus nitrite as nitrogen, dissolved, (colorimetric, low level)
data from the National Water Quality Laboratory
- Orthophosphate as phosphorus, dissolved, (colorimetric) data from the
National Water Quality Laboratory
- Orthophosphate as phosphorus, dissolved, (colorimetric, low level) data
from the National Water Quality Laboratory
- Phosphorus, dissolved, (micro-Kjeldahl digestion, automated segmented
flow, colorimetric) data from the National Water Quality Laboratory
- Phosphorus, dissolved, (colorimetric, low level) data from the National
Water Quality Laboratory
- Phosphorus, dissolved, (U.S. Environmental Protection Agency) data from
the National Water Quality Laboratory
- Phosphorus, whole-water recoverable, (micro-Kjeldahl digestion, automated
segmented flow, colorimetric) data from the National Water Quality Laboratory
- Phosphorus, whole-water recoverable, (colorimetric, low level) data from
the National Water Quality Laboratory
- Phosphorus, whole-water recoverable, (U.S. Environmental Protection
Agency) data from the National Water Quality Laboratory
- Alkalinity, whole-water recoverable, (electrometric titration) data from
the Quality of Water Service Unit laboratory
- Aluminum, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Aluminum, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry, U.S. Environmental Protection Agency) data from the Quality
of Water Service Unit laboratory
- Aluminum, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Arsenic, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Arsenic, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Barium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Barium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Beryllium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Beryllium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Boron, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Cadmium, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Cadmium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Cadmium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Cadmium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Calcium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the Quality of Water Service Unit laboratory
- Calcium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Chloride, dissolved, (ion chromatography) data from the Quality of Water
Service Unit laboratory
- Chromium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Chromium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Chromium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Cobalt, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Copper, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the Quality of Water Service Unit laboratory
- Copper, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Copper, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Copper, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Dissolved solids, dissolved, (gravimetric) data from the Quality of
Water Service Unit laboratory
- Fluoride, dissolved, (ion-selective electrode) data from the Quality of
Water Service Unit laboratory
- Iron, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Iron, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Lead, dissolved, (graphite furnace-atomic absorption spectrophotometry)
data from the Quality of Water Service Unit laboratory
- Lead, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Lead, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Lead, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Magnesium, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the Quality of Water Service Unit laboratory
- Magnesium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Manganese, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Manganese, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Mercury, whole-water recoverable, (cold vapor-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Molybdenum, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Nickel, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Nickel, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Nickel, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Potassium, dissolved, (flame-atomic absorption spectrophotometry) data
from the Quality of Water Service Unit laboratory
- Selenium, dissolved, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Selenium, whole-water recoverable, (graphite furnace-atomic absorption
spectrophotometry) data from the Quality of Water Service Unit laboratory
- Silica, dissolved, (inductively coupled plasma-atomic emission
spectrometry) data from the Quality of Water Service Unit laboratory
- Silica, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Silver, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Sodium, dissolved, (flame-atomic absorption spectrophotometry) data from
the Quality of Water Service Unit laboratory
- Strontium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Strontium, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Sulfate, dissolved, (ion chromatography) data from the Quality of Water
Service Unit laboratory
- Vanadium, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Zinc, dissolved, (inductively coupled plasma-atomic emission
spectrometry, trace) data from the Quality of Water Service Unit laboratory
- Zinc, whole-water recoverable, (inductively coupled plasma-atomic
emission spectrometry, trace) data from the Quality of Water Service Unit
laboratory
- Ammonia as nitrogen, dissolved, data from the Quality of Water Service
Unit laboratory
- Ammonia plus organic nitrogen as nitrogen, dissolved, data from the
Quality of Water Service Unit laboratory
- Ammonia plus organic nitrogen as nitrogen, whole-water recoverable, data
from the Quality of Water Service Unit laboratory
- Nitrate plus nitrite as nitrogen, dissolved, data from the Quality of
Water Service Unit laboratory
- Orthophosphate as phosphorus, dissolved, data from the Quality of Water
Service Unit laboratory
- Phosphorus, dissolved, data from the Quality of Water Service Unit
laboratory
- Phosphorus, whole-water recoverable, data from the Quality of Water
Service Unit laboratory
Back to Top
Back to Report