USGS

Evaluation of Candidate Rain Gages For Upgrading Precipitation Measurement Tools For the National Atmospheric Deposition Program:

Water-Resources Investigations Report 02-4302

By John D. Gordon1

An html version of the abstract is shown below. This report is available as a 11.8 MB pdf file: WRIR 02-4302 

Abstract

            The National Atmospheric Deposition Program (NADP) was established in 1977 to investigate atmospheric deposition and its effects on the environment. Since its establishment, precipitation records have been obtained at all NADP sites using a gage developed approximately 50 years ago-the Belfort 5-780 mechanical rain gage. In 1998 and 1999, a study was done by the U.S. Geological Survey to evaluate four recently developed, technologically advanced rain gages as possible replacement candidates for the mechanical gage currently (2002) in use by the NADP. The gage types evaluated were the Belfort 3200, Geonor T-200, ETI Noah II, and the OTT PLUVIO. The Belfort 5-780 was included in the study to compare the performance of the rain gage currently (2002) used by NADP to the performance of the more recently developed gages. As a reference gage, the NovaLynx Model 260-2510 National Weather Service type stick gage also was included in the study. Two individual gages of each type were included in the study to evaluate precision between gages of the same type. A two-phase evaluation was completed. Phase I consisted of indoor bench tests with known amounts of simulated rainfall applied in 20 individual tests. Phase II consisted of outdoor testing by collecting precipitation during a 26-week period near Bay St. Louis, Mississippi. The ETI Noah II, OTT PLUVIO, and NovaLynx stick gages consistently recorded depths more commensurate with the amounts of applied simulated rainfall in Phase I testing than the Geonor T-200, Belfort 5-780, and Belfort 3200 gages. Gages where both the median difference between the measured and applied simulated rainfall and the interquartile range of all of their measured minus applied simulated rainfall differences were small (less than or equal to 0.01 inch) were judged to have performed very well in Phase I testing. The median and interquartile-range values were 0.01 inch or less for each of the ETI Noah II gages, OTT PLUVIO gages, and NovaLynx stick gages. The performance of the Geonor T-200 and Belfort 3200 gages was affected by technical problems during Phase I testing. As part of the evaluation of Phase II results, the average weekly precipitation totals obtained from the Belfort 5-780 gages and from each of the gages under consideration as possible replacements for the Belfort 5-780 gage were all compared with the average precipitation weekly totals obtained from two NovaLynx stick gages. The median absolute differences between a particular gage model and the NovaLynx stick reference gage for the 26 weeks of outdoor testing ranged from 0.04 inch for the ETI Noah II and OTT PLUVIO gages to 0.06 inch for the Geonor T-200. The total absolute difference between a particular gage type and the reference gage ranged from 1.23 inches for the Belfort 5-780 to 1.83 inches for the Geonor T-200 gages. Because the Belfort 3200 gages were inoperable for most of the Phase II testing, it is not meaningful to include the results from that gage type in a calculation of median or total absolute differences. The OTT PLUVIO proved to be the most reliable gage in Phase I and II testing, operating trouble free over the duration of the study.

CONTENTS

Abstract
Introduction
Previous Rain-Gage Studies
Gages Evaluated in this Study
Methods of Study
Results of Evaluation
Conclusions
Summary
References Cited


1 jgordon@usgs.gov, U.S. Geological Survey, Denver, CO

If you have Adobe Acrobat Reader installed on your computer, you may view and/or print the PDF version of this report. If you do not have Acrobat Reader, you may download it here.

Pdf file of the report: WRIR 02-4302
For additional information write to:

Greg Wetherbee
U.S. Geological Survey
Box 25046, MS 401
Denver Federal Center
Denver, CO 80225
wetherbe@usgs.gov

Copies of this report my be purchased from:

U.S, Geological Survey
Branch of Information Services
Box 25286
Denver Federal Center
Denver, CO 80225
888-ASK-USGS
Precipitation Chemistry Project Home Page BQS Home Page

USGS Water Biology Geology Mapping WRI Pubs Water Related Pubs

U.S. Department of the Interior, U.S. Geological Survey
Maintainer: Natalie Latysh
Last update: April 2003
Privacy Statement || Disclaimer

Users with visual disabilities can visit this site for conversion tools and information to help make PDF files accessible.